Input Voltage: | AC100-240V50/60Hz |
---|---|
Purpose: | Security Camera Use |
Size: | 2A 1A 5A |
Protection: | Short-Circuit Protection |
Transport Package: | 488*266*203mm |
Specification: | 50PCS/Carton |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Input | Input Connecting plug: | EUROPE |
Input voltage | AC100-240V50/60Hz | |
Output |
Output Connector | 5.5 X 2.1mm DC/90mm, |
Output voltage | 3-24V +/-5% |
|
Outputelectric current | 1A | |
Ripple wave | (mVp-p): <1% | |
Linear modulate | ±0.5%max | |
Temperature coefficient | ±0.02%/ºC | |
start time | ≤3s(240VAC output,1o=100%) | |
guard time | ≥20ms(240VAC input,1o=100%) | |
Output Standard | 12V1A | |
Protection | override protection | 115%~200%kvA,automatic recovery |
short-circuit protection | 1 channel:automatic recovery | |
Insulation | insulation strength | 1000VAC/10mA,1MIN |
insulation resistance | ≥30MΩ,DC 500V | |
Environment | working temperature | 0ºC~40ºC,10%~90%RH |
Store temperature | -20ºC~60ºC,10%~90%RH | |
Size | Size/weight | 85X44X29mm/105G |
packaging | 100PCS |
Input Voltage: | 100-240VAC |
Line Frequency: | 50/60Hz |
Current: | 0.3A Max. |
Protection: | Internal Primary Current Fuse, Inrush Limiting |
Configuration: | Horizontal case |
Load Regulation: | +/- 5% (Typical) |
Ripple | 1~2% Vp-p Max. for Output Voltage@Full Load |
Transient Response: | 0.5mS for 50% Load Change Typical |
Hold-up Time: | 10mS @ Full Load |
Protection: | Shor Circuit Protection / Over Voltage Protection / Over Current Protection |
DC Plug: | According to your requirements |
DC Cord: | Flat or Round |
Ferrite Core | Optional |
CE / GS /CB |
EN60950-1, EN61558-1,EN61558-2-16 |
IEC60950-1, IEC61558-1, IEC61558-2-16 |
Topology | Switching Flyback |
Dielectric Withstand | 3200VAC Primary-Secondary |
Leakage Current | 0.25mA |
EMI Conduction & Radiation | EN55022, EN55024,EN55014 |
EMC Immunity | EN61000-3-2 & en61000-3-3 |
MTBF | 100,000 Calculated Hours at 25ºC, by Telcordia SR-332 |
Efficiency | ERP VI / CoC VI certified |
Tests Standard No. | TEST SPECIFICATION Level |
Test Mode Test Ports | Perform. Criteria | Remark |
1. ESD IEC/EN 61000-4-2 |
8KV air discharge 4KV contact discharge |
Direct Mode | B | PASS |
4KV HCP discharge 4KV VCP discharge | Indirect Mode | B | PASS | |
2. RS IEC/EN 61000-4-3 |
80 MHz to 1000 MHz 3V/m(rms), 1 KHz, 80%, AM modulated |
Enclosure |
A |
PASS |
3. EFT/Burst IEC/EN 61000-4-4 |
1.0KV(peak) 5/50ns Tr/Th 5KHz Repetition Freq. |
AC Power Port |
B |
PASS |
0.5 KV(peak) 5/50ns Tr/Th 5KHz Repetition Freq. |
CTL/Signal Data Line Port | B |
N/A |
|
4. Surges IEC/EN 61000-4-5 |
1 KV(5P/5N) 1.2/50(8/20) Tr/Th us |
L-N | B | PASS |
2 KV(5P/5N) 1.2/50(8/20) Tr/Th us |
L-PE N-PE | B | N/A | |
5 Injected Current IEC/EN 61000-4-6 |
0.15 MHz to 230 MHz 3V(rms), 1KHz 80%, AM Modulated 150W source impedance |
CTL/Signal Port |
A |
N/A |
0.15 MHz to 230 MHz 3V(rms), 1KHz 80%, AM Modulated 150W source impedance |
AC Power Port |
A |
PASS |
|
0.15 MHz to230 MHz 3V(rms), 1KHz 80%, AM Modulated 150W source impedance |
DC Power Port |
A |
N/A |
|
6 Volt. Interruptions Volt. Dips IEC/EN 61000-4-11 |
Voltage Dips:
100% reduction for 0.5 period Performance Criterion C |
AC Power Port |
C |
PASS |
Suppliers with verified business licenses